• Me440 Handheld Data Logger Three Phase/ Single Phase Power Meter Measurement and Analysis Instruments Rogowski Coil Solar Power Analyzer
  • Me440 Handheld Data Logger Three Phase/ Single Phase Power Meter Measurement and Analysis Instruments Rogowski Coil Solar Power Analyzer
  • Me440 Handheld Data Logger Three Phase/ Single Phase Power Meter Measurement and Analysis Instruments Rogowski Coil Solar Power Analyzer
  • Me440 Handheld Data Logger Three Phase/ Single Phase Power Meter Measurement and Analysis Instruments Rogowski Coil Solar Power Analyzer
  • Me440 Handheld Data Logger Three Phase/ Single Phase Power Meter Measurement and Analysis Instruments Rogowski Coil Solar Power Analyzer
  • Me440 Handheld Data Logger Three Phase/ Single Phase Power Meter Measurement and Analysis Instruments Rogowski Coil Solar Power Analyzer

Me440 Handheld Data Logger Three Phase/ Single Phase Power Meter Measurement and Analysis Instruments Rogowski Coil Solar Power Analyzer

Display: 3.5 Inch TFT Screen Display
Installation: Direct Connected
Usage: Multi-Functional Energy Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Maximum Demand Meter
Electric Equipment: Three-phase Four-wire
Theory: Electronic Meter
Power Meter Connection: Terminal
Samples:
US$ 450/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
ME440
Measured Signal
Continuous Wave
Type
Energy Meter
Certification
RoHS, ISO, CE
Customized
Customized
Support Extra Sensor
4PCS BNC Terminal 333mv CT Rogowski Coil
Storage
16GB Memory,USB Disk Download
Power 1
2*2900mAh Panasonic Lithium Battery
Power 2
5V DC Power Supply(Included Adaptor)
Poles Description
3pH4w 3pH3w 1pH2w (L-N); 1pH2w(L-L);1pH3w(L-L-N)
Sampling Rate
8K Samples Per Second
Harmonic
51th in The Mean Time
Frequency
45...65 Hz
Rated Current (3 Level Selectable)
600A 3000A 6000A
Voltage
0.2% From 5 to 600V
Power Factor
±0.005
Communication Protocol
Modbus TCP
Current Input
BNC Connector
BNC Connector
Banana Plug
DC Power Supply
DC 5.5*2.1 Plug
Transport Package
Carton
Specification
850g (with Accessory 2kgs)
Trademark
MEATROL
Origin
China
HS Code
9030331000
Production Capacity
50000PCS/Year

Product Description

Me440 Handheld Data Logger Three Phase/ Single Phase Power Meter Measurement and Analysis Instruments Rogowski Coil Solar Power AnalyzerMe440 Handheld Data Logger Three Phase/ Single Phase Power Meter Measurement and Analysis Instruments Rogowski Coil Solar Power Analyzer
 
Connectivity advantages
Model ME440
Support Extra sensor 4pcs BNC terminal 333mV CT
4pcs BNC terminal Rogowski coil
Storage 16GB Memory,USB DISK download
(save intervals 1mins default)
Power 2*2900mAh PANASONIC lithium battery(wroking time: approx 10 hours)
Or 5V DC power supply(included adaptor)



Feature
Specification  
Model ME440  
Product component type Handheld;poly-phase;data logger;power analyzer  
Poles description 3PH4W  3PH3W
1PH2W (L-N); 1PH2W(L-L);1PH3W(L-L-N)
 
Device application Power analysis
Data log
 
Input type External Rogowski coil
External CT(333mV only)
 
Display 3.5 inch TFT screen display  
Sampling rate 8k samples per second  
Harmonic 51th in the mean time  
Mechanical characteristics
Weight 850g (with Accessory 2kgs)
Dimension L*W*D:21.5*13*6CM
Power Meter Characteristics
The power meter measures currents and voltages and reports real-time RMS values for all 3-phases and neutral. In addition, the power meter calculates power factor, realpower, reactive power, and more.
The following sections list the metering characteristics of the power meter.


Real-Time Measuring
The following table lists the metering characteristics of the power meter for the real-time
measurement:
Characteristics Description
Current Per phase, neutral, and average of 3 phases
Voltage L-L, L-N, and average of 3 phases,N-PE
Frequency 45...65 Hz
Active power Total and per phase (signed)
Reactive power Total and per phase (signed)
Apparent power Total and per phase(signed)
Power factor (True) Total and per phase
0.000 to 1 (signed)
Angle Voltage angle,Current angle
Current unbalance Per phase, most unbalanced of 3 phases
Voltage unbalance most unbalanced of 3 phases



Minimum/Maximum Values
When any one-second real-time reading reaches its highest or lowest value, the power meter saves the minimum and maximum values in its nonvolatile memory.
From the power meter display, you can:
• view all min./max. values since the last reset and the reset date and time.
• reset min./max. values.
All running min./max. values are arithmetic minimum and maximum values. For example, the minimum phase A-N voltage is the lowest value in the range from 0 to 999.9GV that has occurred since last reset of the min./max. values.
The power meter provides time stamping for all minimum/maximum values.
The following table lists the minimum and maximum values stored in the power meter:

 
Characteristics Description
Current Per phase and average
Voltage per phase and average
Active power Per phase and total
Reactive power Per phase and total
Apparent power Per phase and total



Demand Readings
The power meter provides the following demand readings.
 
Characteristics Description
Current Per phase and average
Active, reactive, apparent power Per phase and Total
Peak Demand Values  
Current Per phase and average
Active, reactive, apparent power Per phase and Total
Demand Calculation Methods
Power demand is the energy accumulated during a specified period divided by the length of the period. Current demand is calculated using arithmetical integration of the current RMS values during a time period, divided by the length of the period. How the power meter performs this calculation depends on the selected method. To be compatible with electric utility billing practices, the power meter provides block interval power/current demand calculations.
For block interval demand calculations, you select a block of time (interval) that the power meter uses for the demand calculation and the mode the meter uses to handle he interval. 2 different modes are possible:
• Fixed block - Select an interval from 1 to 60 minutes (in 1 minute increments). The
 power meter calculates and updates the demand at the end of each interval.
• Sliding block - Select an interval from 1 to 60 minutes (in 1 minute increments). For demand intervals less than 15                 minutes, the value is updated every 15 seconds. For demand intervals of 15 minutes and greater, the demand value is updated every 60 seconds. The power meter displays the demand value for the last completed interval.



The following figures illustrate the 2 ways to calculate demand power using the block
method. For illustration purposes, the interval is set to 15 minutes.


Peak Demand
In nonvolatile memory, the power meter maintains a maximum operating demand value called peak demand. The peak is the highest value (absolute value) for each of these readings since the last reset.
You can reset peak demand values from the power meter display. You should reset peak demand after changes to basic power meter setup such as power system configuration.
Energy Readings
The power meter calculates and stores Per phase and total energy values for active,reactive, and apparent energy.
You can view energy values from the display. The resolution of the energy value automatically changes from kWh to MWh to GWh (kVAh to MVARh to GWh).
The energy values automatically resets to 0 when it reaches the limit of 999.9GWh,
999.9GVAh, or 999.9GVARh.

The following table lists the energy readings from the power meter:
Characteristics Description
Energy values  
Active energy 0 to 999.9GWh
Auto reset to 0 in case of over limit
Reactive energy 0 to 999.9GVARh
Auto reset to 0 in case of over limit
Apparent energy 0 to 999.9GVAh
Auto reset to 0 in case of over limit

Power Quality Analysis Values
The power quality analysis values use the following abbreviations:


• Fundamental phase current rms: I1
• Fundamental phase voltage rms: V1
• RMS of up to three harmonics of phase current:
 Ix, Iy, Iz, x, y, z = 2, 3,…, N
• RMS of up to three harmonics of phase voltage:
 Vx, Vy, Vz, x, y, z = 2, 3,…, N

•Total harmonic distortion of the phase current

• Total harmonic distortion of the phase voltage

• Harmonic distortion of up to three harmonics on the phase
current


• Harmonic distortion of up to three harmonics on the phase
voltage:


THD provides a measure of the total distortion present in a waveform. THD is the ratio of harmonic content to the fundamental and provides a general indication of the quality of a waveform. THD is calculated for both voltage and current.
The following table lists the power quality values of the power meter:



 
Characteristics Description
THD Total,2,3,4,5,,,,,51(51 times) Per phase current (percentage value)
X,Y,Z,A,B(5 times each time) Per phase current(rms value)
Total,2,3,4,5,,,51(51 times)Per phase voltage(percentage value)
X,Y,Z,A,B(5 times each time)Per phase voltage(rms value)
 


Data Record
The power meter records data to SD card, the following table lists data record of the power meter.
Record
Record interval 1s to 9999s(default 1min)
Record format csv
Record capacity 16GB Memory
Store about 2.5K Bytes data each time
record 12 years (1min interval)
Record data "Current Harmonic"file ITHD(%),IHD2(%),IHD3(%),,,,,IHD51(%) (Each phase )
"Voltage Harmonic"file UTHD(%),UHD2(%),UHD3(%),,,,,UHD51(%)(Each phase)
"DataSheet" file Voltage(V);UTHD(%);Current(A);ITHD(%);
Frequency(Hz);Power Factor;
Current Demand(A);
Current Peak Demand(A)&Date;
(Each phase and Average)
Active Power(W) ;Reactive Power(Var);Apparent Power(Va)
Active Energy(Wh);Reactive Energy(Varh);Apparent Energy(Vah)
(Each phase and Summary)
Total Active Power Deamnd(W)
Total Active Power Peak Deamnd(W)&Date
Total Reactive Power Deamnd(Var)
Total Reactive Power Peak Deamnd(Var)&Date
Total Apparent Power Deamnd(Va)
Total Apparent Power Peak Deamnd(Va)&Date


Other Characteristics
The following table lists other characteristics of the power meter:
Characteristics Description
Reset  
Minimum and maximum values -
Peak demand values -
Current demand calculation method 1 to 60 minutes
Power demand calculation method 1 to 60 minutes
Environmental conditions
Operating temperature -25ºC to +55ºC
Storage temperature -40ºC to +85ºC
Humidity rating 5 to 95% RH at 50ºC(non-condensing)
Pullution degree 2
Overvoltage category III,for distribution systems up to 277/480VAC
Dielectric withstand As per IEC61010-1, Doubled insulated front panel display
Altitude 3000m Max
IP degree of protection IP20 conforming to IEC 60629
Colour White
Contractual warranty 12months
EMC
Electrostatic discharge Level IV(IEC61000-4-2)
Immunity to radiated fields Level III (IEC61000-4-3)
Immunity to fast transients Level IV (IEC61000-4-4)
Immunity to surge Level IV (IEC61000-4-5)
Conducted immunity Level III (IEC61000-4-6)
Immunity to power frequency magnetic fields 0.5mT (IEC61000-4-8)
Conducted and radiated emissions Class B (EN55022 )
Standard compliance
EN 62052-11,EN61557-12,EN 62053-21,EN 62053-22,EN 62053-23,EN 50470-1,EN 50470-3,
EN 61010-1,EN 61010-2,EN 61010-031


Specification
Measurement accuracy
Rated current (3 level selectable) 600A(0.5% from 6A to 720A)   
3000A(0.5% from 10A to 3600A)  
6000A(0.5% from 20A to 7200A)  
Rogwoski coil connect setting 600A MRC-36
3000A NRC-150 or Y-FCT-510
6000A NRC-200 or Y-FCT-800
CTs connect setting Primary setting: from 1A to 999999A
Secondary setting: from 0.001mV to 707mV
Voltage 0.2% from 5 to 600V
Power factor ±0.005
Active/Apparent Power IEC62053-22 Class 0.5
Reactive power IEC62053-21 Class 2
Frequency 0.01% from 45 to 65Hz
Active energy IEC62053-22 Class 0.5s
Reactive energy IEC62053-21 Class 2
Input-current characteristics
Primary current range 600A       0.5A to 720A
3kA        0.5A to 3600A
6kA        0.5A to 7200A
Measurement input range 1/225mV-707mV
Permissible overload 2V for 10s/hours
Power Supply
Power 2*2900mAh PANASONIC lithium battery
Working time: 10 hours
Charging time: 8 hours
5V DC power supply(included adaptor)
power consumption
Screen Maximum Brightness 2000mW
Screen Minimum Brightness 1800mW
Wire diameter for terminals
Current input BNC connector
Voltage input Banana plug
DC power supply DC 5.5*2.1 plug
 


MODBUS-TCP
 
Communication
Transmission mode RJ45 port
Communication protocol MODBUS TCP
Settings
IP address Configurable (default 192.168.1.5)
Port No. 502


Port definition
 
Port number Port name Port function Remarks
1 IA A-phase current input Current input
2 IB B-phase current input
3 IC C-phase current input
4 In N-phase current input
5 UN N-phase voltage input Voltage input
6 UC C-phase voltage input
7 UB B-phase voltage input
8 UA A-phase voltage input
9 UE PE-N voltage input
10 Power POWER 5V DC Power 5-9V DC
11 USB port Download log data Plug out(in) USB DISK
12 RJ45 port Mobus-TCP communication Communication

Accessories
Accessories
Voltage wires 5pcs voltage clamp wires with banana plug (2 meters,1.5mm²)
Adaptor 85-265 AC to 5V DC adaptor(default Europe plug)
Remark Rogowski coil not included

Me440 Handheld Data Logger Three Phase/ Single Phase Power Meter Measurement and Analysis Instruments Rogowski Coil Solar Power Analyzer
Me440 Handheld Data Logger Three Phase/ Single Phase Power Meter Measurement and Analysis Instruments Rogowski Coil Solar Power AnalyzerMe440 Handheld Data Logger Three Phase/ Single Phase Power Meter Measurement and Analysis Instruments Rogowski Coil Solar Power Analyzer

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Plant Area
897 square meters
Management System Certification
ISO9001:2015