• STP High Accuracy Electronic Transformer 333mv Output
  • STP High Accuracy Electronic Transformer 333mv Output
  • STP High Accuracy Electronic Transformer 333mv Output
  • STP High Accuracy Electronic Transformer 333mv Output
  • STP High Accuracy Electronic Transformer 333mv Output
  • STP High Accuracy Electronic Transformer 333mv Output

STP High Accuracy Electronic Transformer 333mv Output

Type: Rogowski
Output Signal Type: Analog Output
Production Process: Integration
Material: Metal
Accuracy Grade: 0.5G
Application: All Electronic, Electrical, Electric Related Cases
Samples:
US$ 40/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
STP/NRC-200
IP Rating
IP20
Certification
CE
Customized
Customized
Current Range(RMS)
0.5-100ka AC
Output
150mv, 333mv, 500mv, 1V, 1.5V, 3V
Accuracy(Typ.)
Calibrated <0.5% (Central Position, 25ºC)
Bandwidth
20Hz to 2kHz
Power Supply
3.3V-5V DC
Power Consumption
≤ 20MW
Terminal
RJ45/ 8pin
Built-in Integrator
Selectable
Linearity
±0.2% (5%-200%)
Phase Error
≤0.5°
Output on 0A(Zero Drift)
≤2mv
Temperature Drift
200ppm/ºC
Operating Temperature
-20ºC to 70ºC
Storage Temperature
-30ºC to 90ºC
Relative Humidity
80% Max. Without Condensation
Transport Package
Poly Bag, Standard Export Carton
Specification
CE
Trademark
Meatrol
Origin
Shanghai
HS Code
8504311000
Production Capacity
50000PCS/Month

Product Description

STP High Accuracy Electronic Transformer 333mv Output

STP Splitter
STP High Accuracy Electronic Transformer 333mv Output
STP High Accuracy Electronic Transformer 333mv Output


 
Three in one STP splitter (Built-in integrator selectable)

The product description

STP with an selectable built-in integrator that outputs a three-way Rogowski coil signal through an RJ45 port or 8 Pin. Power supply 3.3 ~ 5V , 150mV, 333mV, 500mV, 1V, 1.5V, 3V AC output is optional.

Advantage

Portable mini, easy for installationl
 
Analog connection diagram

STP High Accuracy Electronic Transformer 333mv Output
Size chart
STP High Accuracy Electronic Transformer 333mv Output
RJ45 connector definition
STP High Accuracy Electronic Transformer 333mv Output
Specification
 
MODEL STP
Rated output
 
 
100A
600A
1000A
3000A
6000A 
....
Rated output 333mV AC
Maximum Output(overload) 3V rms
Power supply 3.3V-5V DC
Power consumption ≤20mW
Bandwidth 20Hz-2kHz
Read Accuracy 1% typical at 1%(≥10A) to 200% of rated Current @25ºC
Linearity ±0.2% (5% - 200% )
Phase error ≤0.5°
Minimum Current measurement 0.5A (Ripple 100mA)
Output on 0A  (zero drift) ≤2mV
Temperature drift 200ppm/ºC
Operating temperature -20ºC - 70ºC
Storage temperature -30ºC - 90ºC
Relative humidity: 80% max.without condensation
Protection degree: IP20
Other requirements, please contact us to OEM.
STP High Accuracy Electronic Transformer 333mv Output
Safety instructions
The coil is only safe if used within the appropriate parameters. Please read the following instructions carefully
You can download the latest product instructions on our rogowski website.

Warning!
Ignoring this warning can lead to serious danger!
The Roche coil can only be installed and operated by professionals with electrical training and qualifications.
The installation or operation shall comply with the applicable national security regulations and the relevant
manufacturer's instructions. Used in electrical or electronic equipment that meets parameters and safety
requirements..


Electric shock warning!
Some parts of the module may carry dangerous voltages when operating the Roche coil. The user should ensure
that all necessary measures are taken to prevent electric shock. A Roche coil is a built-in device containing
conductive parts that should not be touched after installation. A protective cover or additional insulation may be
required.
When the equipment breaks down and needs to be repaired. Unless it is confirmed that there are no hazardous
live modules in or near this power system, operations such as maintenance should be carried out after the main
power supply is disconnected.

Only when properly transported, stored, installed, and carefully operated and maintained can the coil be safely
and trouble-free.


Attention!

Do not damage the coil. Twisting, pricking, over-squeezing, over-bending will greatly reduce the accuracy and
service life of the equipment.

What is a Rogowski coil?
Rogowski coils have been used for the detection and measurement of electric currents for decades. They are based on a simple principle: an "air-cored" coil is placed around the conductor in a toroidal fashion and the magnetic field produced by the current induces a voltage in the coil. The voltage output is proportional to the rate of change of current. This voltage is integrated, thus producing an output proportional to the current.
By using precision winding techniques, especially developed for the purpose, the coils are manufactured so that their output is not influenced by the position of the conductor within the toroid, and to reject interference from external magnetic fields caused, for example, from nearby conductors.Basically, a Rogowski coil current measuring system consists of a combination of a coil and conditioning electronics.Rogowski coil current transducers are used for the AC measurement.
They can be used in similar circumstances to current transformers but for many applications they have considerable advantages:
Wide dynamic range.
High linearity.
Very useful with large size or awkward shaped conductors or in places with limited access. Thanks to the structure without hard core, the coil can be easily manufactured according to the application or to the available space.
Unlike traditional current transducers, there is no danger from open-circuited secondaries.
They cannot be damaged by large overloads.
They are non-intrusive. They draw no power from the main circuit carrying the current to be measured.
They are also light weighted and in some applications are light enough to be suspended on the conductor being measured.

The transducer does not measure direct currents but, unlike a current transformer, it can carry out accurate measurements of AC component even if there is a large superimposed DC component, since there is no iron core causing saturation. This feature is particularly useful for measuring ripple currents for example in battery charging systems.


MEATROL Rogowski coil Model No. Definition:

STP High Accuracy Electronic Transformer 333mv Output
Description Connector model Window size B Signal cable length E Ratio Model No.
Calibrated
(mV/kA@50Hz)
Uncalibrated
(mV/kA@50Hz)
Ø 6 Mini type
with fixing ribbon ties
MRC 16 2m 50
(60mV/kA@60Hz)
60
(72mV/kA@60Hz)
MRC-16-2m-50
24 MRC-24-2m-50
36 MRC-36-2m-50
Ø8 Rotate bayonet type
Easy installation
with fixing ribbon ties
NRC 100 2m 85 105 NRC-100-2m-85
150 85 NRC-150-2m-85
200 50 NRC-200-2m-50
Ø12 High Voltage
36kV
D-SRC 50 2m ________ 60
(72mV/kA@60Hz)
D-SRC-50-2m-60
100 D-SRC-100-2m-60
150 D-SRC-150-2m-60
Ø12 High Sensitivity SRC 50 2m 333 360 SRC-50-2m-333
100 SRC-100-2m-333
150 SRC-150-2m-333
Ø 6 precision type TRC 16 2m 50 60 TRC-16-2m-50
24 TRC-24-2m-50
36 TRC-36-2m-50
Ø8 Snap-in type
Easy installation
ZRC 50 2m 100 / 85 / 50 105 ZRC-50-2m-85
100 ZRC-100-2m-85
150 ZRC-150-2m-85
Ø8 Spiral joint
Suitable for long term stable installation
Y-FCT B50 2m 85 110 Y-FCT-B50-2m-85
B100 85 Y-FCT-B100-2m-85
B150 85 Y-FCT-B150-2m-85
B240 50 Y-FCT-B240-2m-50
Ø8 High Frequency H-FCT B50 2m 1.2 / 6.8 / 10   H-FCT-B50-2m-10
B95   H-FCT-95-2m-10

https://shpytech.en.made-in-china.com/product/QFBtYorXXpWb/China-Rogowski-Coil-Handheld-Digital-Power-Quality-Analyzer-with-TFT-Display.html

https://shpytech.en.made-in-china.com/product/WwvtlOXKMmrB/China-Flexible-Rogowski-Coil-Ratio-50mv-Ka-Air-Cored-Current-Sensor-Coil-Current-Transducer.html

STP High Accuracy Electronic Transformer 333mv Output
STP High Accuracy Electronic Transformer 333mv OutputSTP High Accuracy Electronic Transformer 333mv OutputSTP High Accuracy Electronic Transformer 333mv Output



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Plant Area
897 square meters
Management System Certification
ISO9001:2015