Customization: | Available |
---|---|
Type: | Rogowski Coil Integrator |
Output Signal Type: | 5A AC |
Still deciding? Get samples of US$ 120/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Advantages • High read accuracy 0.5% • 5 current measuring ranges • High bandwidth for measurement 30 to 5kHz • Output 5A rms Related Products • Y-FCT,ZRC,NRC,MRC |
Applications • Measuring devices, lab instrumentation • Power monitoring & analysis • Harmonics and transients monitoring • Welding machine control • High current measurement |
Model | DA05-5 | |
Rated output | 5A AC rms | |
Maximum Output(overload) | 5.5A AC rms(for short term) | |
Rated ratio(DIP switches) | S1: 100A S2: 600A S3: 1000A S4: 3000A S5: 6000A |
|
Potential meters | 100A | MRC-24 (50mV/kA@50Hz) |
600A | MRC-36 (50mV/kA@50Hz) | |
1000A | NRC-100 (85mV/kA@50Hz) | |
3000A | NRC-150 (85mV/kA@50Hz) | |
6000A | NRC-200 (50mV/kA@50Hz) | |
Read Accuracy | 0.5% typical at 1%(≥10A) to 110% of rated Current @25ºC | |
Phase error | ≤0.5° | |
Linearity | ±0.2% of reading(10% to 120% of range) | |
Bandwidth | 30Hz to 5kHz | |
Maximum Burden | 0.2Ω(each phase) | |
Measurement | Secondary CT to measure output of integrator | |
Power consumption | ≤15W | |
Output on 0A (zero drift) | ≤0.5A@1000A | |
Temperature drift | 50ppm/ºC | |
Weight | 220g | |
Dimension | 105*75*45mm | |
Power supply | 24V DC(≥15W) | |
Operating temperature | -20ºC to 70ºC | |
Storage temperature | -30ºC to 90ºC | |
Relative humidity | 80% max.without condensation | |
Protection degree | IP20 | |
NOTE | Integrator can not be installing in the load which already flow more than 20% of rated current before integrator power on. Shut down the primary current(or disconnect the coils) and wait for 10 seconds when Integrator RED light flashes. |
|
Other requirements,please contact us to OEM. |
Coil Model | Coil diameter (mm) | Output ratio and tolerance | Signal cable length |
Code:Y-FCT | Code:200(Typical rated 500A) Code:350(Typical rated 1500A) Code:510(Typical rated 3kA) Code:800(Typical rated 10kA) Y-FCT code is length. |
Code:110 110mV/kA@50Hz±5% Code:100 100mV/kA@50Hz±0.5% Code:85 85mV/kA@50Hz±0.5% Code:50 50mV/kA@50Hz±0.5% |
Code:-2m Code:-5m Code:-10m Code:-20m |
Code:NRC | Code:100(Typical rated 1kA) Code:150(Typical rated 3kA) Code:200(Typical rated 6kA) |
||
Code:MRC | Code:16(Typical rated 100A) Code:24(Typical rated 300A) Code:36(Typical rated 600A) |
Code:60 60mV/kA@50Hz±5% Code:50 50mV/kA@50Hz±0.5% |
|
Code:SRC | Code:50 Code:100 Code:150 |
Code:360 360mV/kA@50Hz±5% Code:333 333mV/kA@50Hz±0.5% Code:100 100mV/kA@50Hz±0.5% Code:85 85mV/kA@50Hz±0.5% Code:50 50mV/kA@50Hz±0.5% |
|
Other requirement could be OEM |