Customization: | Available |
---|---|
Transport Package: | Carton |
Specification: | 125*80*37mm |
Still deciding? Get samples of US$ 75/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | A05 |
Rated output | 5A AC rms |
Maximum Output(overload) | 5A AC rms |
Rated ratio | 100A 600A 1000A 3000A 6000A |
Read Accuracy | 0.5% typical at 1%(≥10A) to 100% of rated Current @25ºC |
Phase error | ≤0.5° |
Linearity | ±0.2% of reading(10% to 100% of range) |
Bandwidth | 30Hz to 5kHz(-3dB) |
Maximum Burden | 0.8Ω |
Measurement | Secondary CTs to measure output of integrator |
Power consumption | 80W |
Output on 0A (zero drift) | ≤0.05A |
Temperature drift | 200ppm/ºC |
Weight | 850g |
Dimension | 125*80*37mm |
Power supply | 85~265V AC/DC(Powered from 2pcs 85-265 to 8VDC 40W SMPS) |
Operating temperature | -20ºC to 70ºC |
Storage temperature | -30ºC to 90ºC |
Relative humidity | 80% max.without condensation |
Protection degree | IP20 |
Other requirements,please contact us to OEM. |
Coil Model | Coil diameter (mm) | Output ratio and tolerance | Signal cable length |
Code:Y-FCT | Code:200(Typical rated 500A) Code:350(Typical rated 1500A) Code:510(Typical rated 3kA) Code:800(Typical rated 10kA) Y-FCT code is length. |
Code:110 110mV/kA@50Hz±5% Code:100 100mV/kA@50Hz±0.5% Code:85 85mV/kA@50Hz±0.5% Code:50 50mV/kA@50Hz±0.5% |
Code:-2m Code:-5m Code:-10m Code:-20m |
Code:NRC | Code:100(Typical rated 1kA) Code:150(Typical rated 3kA) Code:200(Typical rated 6kA) |
||
Code:MRC | Code:16(Typical rated 100A) Code:24(Typical rated 300A) Code:36(Typical rated 600A) |
Code:60 60mV/kA@50Hz±5% Code:50 50mV/kA@50Hz±0.5% |
|
Code:SRC | Code:50 Code:100 Code:150 |
Code:360 360mV/kA@50Hz±5% Code:333 333mV/kA@50Hz±0.5% Code:100 100mV/kA@50Hz±0.5% Code:85 85mV/kA@50Hz±0.5% Code:50 50mV/kA@50Hz±0.5% |
|
Other requirement could be OEM |