Three Phase RS485 Modbus RTU Panel Digital Power Meter

Product Details
Customization: Available
After-sales Service: Any Problem, We Will Send 1PCS New for Replacement
Warranty: 1 Year
Manufacturer/Factory & Trading Company
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Plant Area
897 square meters
Management System Certification
ISO9001:2015
  • Three Phase RS485 Modbus RTU Panel Digital Power Meter
  • Three Phase RS485 Modbus RTU Panel Digital Power Meter
  • Three Phase RS485 Modbus RTU Panel Digital Power Meter
  • Three Phase RS485 Modbus RTU Panel Digital Power Meter
  • Three Phase RS485 Modbus RTU Panel Digital Power Meter
  • Three Phase RS485 Modbus RTU Panel Digital Power Meter
Find Similar Products

Basic Info.

Model NO.
ME435
Display
TFT Color Display
Installation
Direct Connected
Usage
Multi-Functional Energy Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Maximum Demand Meter
Electric Equipment
Three-phase Four-wire
Theory
Electronic Meter
Power Meter Connection
Terminal
Measured Signal
Continuous Wave
Type
Energy Meter
Certification
RoHS, ISO, CE
Customized
Customized
Support Extra Sensor
333mv CT and Rogowski Coil
Install Style
Handheld
Power
4*AA Battery/USB Type-C
Poles Description
3pH4w 3pH3w 1pH2w (L-N); 1pH2w(L-L);1pH3w(L-L-N)
Frequency
0.01% From 45 to 65Hz
Rated Current
5 Level Selectable (100A/600A/1ka/3ka/6ka)
Voltage
0.2% From 60V to 500V
Power Factor
0.005
Harmonic
52th Max
Storage
1GB SD Card(Max 4GB) (Save Intervals 1mins Default
Dimension
L*W*D:21.5*10*3.5cm
Full Parameter Record
1GB SD Card
Data Acquisition Rate
Store About 1K Bytes Data Each Time
Mounting Mode
Clip-on
Record Format
Csv
Transport Package
Carton
Specification
350g
Trademark
MEATROL
Origin
China
HS Code
9030331000
Production Capacity
50000PCS/Year

Product Description

Three Phase RS485 Modbus RTU Panel Digital Power Meter
ME435 Poly-phase
Handheld Power Meter
Three Phase RS485 Modbus RTU Panel Digital Power Meter
 
Connectivity advantages
Model ME435
Support Extra sensor  BNC terminal 333mV CT
BNC terminal Rogowski coil
Storage 1GB SD card(Max 4GB)
(save intervals 1mins default)
Power 4*AA battery(wroking time: approx 7 hours)
Or USB Type-C

Feature
Specification  
Model ME435  
Product component type Handhold  poly-phase  power meter  
Poles description 3PH4W  3PH3W
1PH2W (L-N); 1PH2W(L-L);1PH3W(L-L-N)
 
Device application Power analysis
Energy meter
 
Input type External Rogowski coil
External CT(333mV only)
 
Display 3.5 inch TFT screen display  
Sampling rate 8k samples per second  
Harmonic 52th Max  
Mechanical characteristics
Weight 350g
Dimension L*W*D:21.5*10*3.5CM
Power Meter Characteristics
The power meter measures currents and voltages and reports real-time RMS values for all 3-phases and neutral. In addition, the power meter calculates power factor, realpower, reactive power, and more.
The following sections list the metering characteristics of the power meter.

Real-Time Measuring
The following table lists the metering characteristics of the power meter for the real-time
measurement:
Characteristics Description
Current Per phase, neutral, and average of 3 phases
Voltage L-L, L-N, and average of 3 phases
Frequency 45...65 Hz
Active power Total and per phase (signed)
Reactive power Total and per phase (signed)
Apparent power Total and per phase(signed)
Power factor (True) Total and per phase
0.000 to 1 (signed)
Angle Voltage angle,Current angle
Current unbalance Per phase, most unbalanced of 3 phases
Voltage unbalance most unbalanced of 3 phases

Minimum/Maximum Values
When any one-second real-time reading reaches its highest or lowest value, the power meter saves the minimum and maximum values in its nonvolatile memory.
From the power meter display, you can:
• view all min./max. values since the last reset and the reset date and time.
• reset min./max. values.
All running min./max. values are arithmetic minimum and maximum values. For example, the minimum phase A-N voltage is the lowest value in the range from 0 to 999.9GV that has occurred since last reset of the min./max. values.
The power meter provides time stamping for all minimum/maximum values.
The following table lists the minimum and maximum values stored in the power meter:

 
Characteristics Description
Current Per phase and average
Voltage per phase and average
Active power Per phase and total
Reactive power Per phase and total
Apparent power Per phase and total

Demand Readings
The power meter provides the following demand readings.
 
Characteristics Description
Current Per phase and average
Active, reactive, apparent power Per phase and Total
Peak Demand Values  
Current Per phase and average
Active, reactive, apparent power Per phase and Total

Data Record
The power meter records data to SD card, the following table lists data record of the power meter.
Record
Record interval 1s to 9999s(default 1min)
Record format csv
Record capacity Micro SD card 1GB(default)
Store about 1K Bytes data each time
record 2 years (1min & 1GB)
Record data Date&time,
Voltage(V),UTHD(%),Current(A),ITHD (%),
ITHD3(%),ITHD5(%), ITHD7(%), ITHD11(%), ITHD13(%),
ITHD3(A), ITHD5(A), ITHD7(A), ITHD11(A), ITHD13(A)
Frequency(Hz), PF(power factor),
Active Power(W),Reactive Power(Var),Apparent Power(Va),
Active Energy(Wh),Reactive Energy(Varh),Apparent Energy(Vah)
Current Demand(A),Current Peak Demand(A)&Date
Total Active Power Deamnd(W)
Total Active Power Peak Deamnd(W)&Date
Total Reactive Power Deamnd(W)
Total Reactive Power Peak Deamnd(W)&Date
Total Apparent Power Deamnd(W)
Total Apparent Power Peak Deamnd(W)&Date


Other Characteristics
The following table lists other characteristics of the power meter:
Characteristics Description
Reset  
Minimum and maximum values -
Peak demand values -
Current demand calculation method 1 to 60 minutes
Power demand calculation method 1 to 60 minut
Environmental conditions
Operating temperature -25ºC to +55ºC
Storage temperature -40ºC to +85ºC
Humidity rating 5 to 95% RH at 50ºC(non-condensing)
Pullution degree 2
Overvoltage category III,for distribution systems up to 277/480VAC
Dielectric withstand As per IEC61010-1, Doubled insulated front panel display
Altitude 3000m Max
IP degree of protection IP20 conforming to IEC 60629
Colour White
Contractual warranty 12months
EMC
Electrostatic discharge Level IV(IEC61000-4-2)
Immunity to radiated fields Level III (IEC61000-4-3)
Immunity to fast transients Level IV (IEC61000-4-4)
Immunity to surge Level IV (IEC61000-4-5)
Conducted immunity Level III (IEC61000-4-6)
Immunity to power frequency magnetic fields 0.5mT (IEC61000-4-8)
Conducted and radiated emissions Class B (EN55022 )
Standard compliance
EN 62052-11,EN61557-12,EN 62053-21,EN 62053-22,EN 62053-23,EN 50470-1,EN 50470-3,
EN 61010-1,EN 61010-2,EN 61010-031

Specification
Measurement accuracy
Rated current (5 level selectable) 100A(0.5% from 10A to 120A)   
600A(0.5% from 10A to 720A)  
1000A(0.5% from 10A to 1200A)  
3000A(0.5% from 30A to 3600A) 
6000A(0.5% from 60A to 7200A) 
Rogwoski coil connect setting 100A MRC-16
600A MRC-36
1000A Y-FCT-200 or Y-FCT-350 or NRC-100
3000A NRC-150 or Y-FCT-510
6000A NRC-200 or Y-FCT-800
CTs connect setting Primary setting: from 1A to 999999A
Secondary setting: from 0.001mV to 333mV
Voltage 0.2% from 60V to 500V
Power factor ±0.005
Active/Apparent Power IEC62053-22 Class 0.5
Reactive power IEC62053-21 Class 2
Frequency 0.01% from 45 to 65Hz
Active energy IEC62053-22 Class 0.5s
Reactive energy IEC62053-21 Class 2
Input-current characteristics
Primary current range 100A       0.5A to 120A
600A       0.5A to 720A
1kA        1A to 1200A
3kA        3A to 3600A
6kA        6A to 7200A
Measurement input range 1/225mV-333mV
Permissible overload 600mV for 10s/hours
Power Supply
Power 4*AA battery(working time: approx. 7hours)
USB Type-C
power consumption
Screen Backlight On 1100mW
Screen Backlight Off 900mW
Wire diameter for terminals
Current input BNC connector
Voltage input Banana plug
DC power supply DC 5.5*2.1 plug

Port definition
 
Port number Port name Port function Remarks
1 IA A-phase current input Current input
2 IB B-phase current input
3 IC C-phase current input
4 UN N-phase voltage input Voltage input
5 UC C-phase voltage input
6 UB B-phase voltage input
7 UA A-phase voltage input
8 Power USB Type-C USB Type-C
9 Micro SD SD card Take out(in) SD card

Accessories
Accessories
Voltage wires 4pcs voltage clamp wires with banana plug (2 meters,1.5mm²)
Adaptor 85-265 AC to 9V DC adaptor
SD card 1GB
Remark Rogowski coil and AA battery not included

Configuration mode
The default factory settings are listed in the following table:
 
Function Factory settings
Wiring 3PH4W;
VT Direction connection;
3 Rcoils on I1, I2, and I3
50Hz
 Ratio Rcoil FSA=1000A
VT ratio=NA
SD Card Switch=ENABLE
Period=60s
Harmonic H1=3
H2=5
H3=7
H4=9
H5=11
Password(Low) 1000
Date/Time -
BackLight Switch=ON
Period=60s
Backlight=5
Demand Method: sliding block;
Interval: 15 minutes

 
Three Phase RS485 Modbus RTU Panel Digital Power MeterThree Phase RS485 Modbus RTU Panel Digital Power Meter

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now