Customization: | Available |
---|---|
Type: | Rogowski |
Output Signal Type: | Analog Output |
Still deciding? Get samples of US$ 55/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Advantage • 12mm section grants high effective isolation • Lower zero drift down to 0.1mV • Voltage-resistant level:36kV Related Products S1 D1 S10 SW DA01 DA05 ME631 |
Applications • Measuring devices, lab instrumentation • Power monitoring & control systems • Harmonics and transients monitoring • Very high current monitoring |
MODEL | D-SRC-50 | D-SRC-100 | D-SRC-150 |
Coil length | 180mm | 380mm | 555mm |
Window size | 50mm | 100mm | 150mm |
Coil Resistance | 85 (+/-10) Ω | 170 (+/-10) Ω | 255 (+/-10) Ω |
Reference Rated current |
≤100kA | ||
Weight | 160- 190g | ||
Ratio Uncalibrated | 60mV/kA@50Hz, 72mV/kA@60Hz | ||
Read Accuracy | Uncalibrated < 5% tolerance (central position, 25ºC) | ||
Maximum current measurable | 100kA | ||
Voltage-resistant level | 36kV | ||
Coil Section | 12mm | ||
Lead length | 2 meter | ||
Temperature | Uncalibrated 200ppm/C | ||
Calibrated 300ppm/C | |||
Position Error | ±2% maximum | ||
Output on 0A (zero drift) | ≤0.05mV | ||
Phase error | ≤0.5° | ||
Linearity | ±0.2% of reading | ||
Bandwidth | 1Hz to 100kHz(-3dB) | ||
Operating temperature | -40ºC to 85ºC | ||
Storage temperature | -50ºC to 90ºC | ||
For other requirements, please contact us for customization. |
Conductor Position | Typical Error(%) |
Adjacent to the center of coil | <0.5% |
Adjacent to the inside edge of coil | <2% |
Coil & cable | Thermoplastic rubber flame retardant UL 94 V-0 rated |
Couplings | PP Flame-Retardant, UL 94 V-O rated |
Color(coil) | Orange, Grey |
Shield | 100% coil, 100% output cable |
Certifications | CE marked |
Complies with LVD EN 61010-1:2010 EMC EN 61326-1:2013 |
|
IP65 | |
Voltage insulation | Coil: 2000V |
Signal cable:1000V | |
Safety | 1000V CATIII ,600V CATIV |
Dimensions(mm) | D-SRC-50 | D-SRC-100 | D-SRC-150 |
A.Windows size A | 80 | 115 | 175 |
B.Windows size B | 50 | 100 | 150 |
C.Coil O.D. | 104 | 139 | 199 |
D.Coil section | 12 | ||
E.Lead Cable Total Length | 2000 | ||
F:Coil length | 275 | 380 | 550 |
Description | Connector model | Window size B | Signal cable length E | Ratio | Model No. | |
Calibrated (mV/kA@50Hz) |
Uncalibrated (mV/kA@50Hz) |
|||||
Ø 6 Mini type with fixing ribbon ties |
MRC | 16 | 2m | 50 (60mV/kA@60Hz) |
60 (72mV/kA@60Hz) |
MRC-16-2m-50 |
24 | MRC-24-2m-50 | |||||
36 | MRC-36-2m-50 | |||||
Ø8 Rotate bayonet type Easy installation with fixing ribbon ties |
NRC | 100 | 2m | 85 | 105 | NRC-100-2m-85 |
150 | 85 | NRC-150-2m-85 | ||||
200 | 50 | NRC-200-2m-50 | ||||
Ø12 High Voltage 36kV |
D-SRC | 50 | 2m | ________ | 60 (72mV/kA@60Hz) |
D-SRC-50-2m-60 |
100 | D-SRC-100-2m-60 | |||||
150 | D-SRC-150-2m-60 | |||||
Ø12 High Sensitivity | SRC | 50 | 2m | 333 | 360 | SRC-50-2m-333 |
100 | SRC-100-2m-333 | |||||
150 | SRC-150-2m-333 | |||||
Ø 6 precision type | TRC | 16 | 2m | 50 | 60 | TRC-16-2m-50 |
24 | TRC-24-2m-50 | |||||
36 | TRC-36-2m-50 | |||||
Ø8 Snap-in type Easy installation |
ZRC | 50 | 2m | 100 / 85 / 50 | 105 | ZRC-50-2m-85 |
100 | ZRC-100-2m-85 | |||||
150 | ZRC-150-2m-85 | |||||
Ø8 Spiral joint Suitable for long term stable installation |
Y-FCT | B50 | 2m | 85 | 110 | Y-FCT-B50-2m-85 |
B100 | 85 | Y-FCT-B100-2m-85 | ||||
B150 | 85 | Y-FCT-B150-2m-85 | ||||
B240 | 50 | Y-FCT-B240-2m-50 | ||||
Ø8 High Frequency | H-FCT | B50 | 2m | 1.2 / 6.8 / 10 | H-FCT-B50-2m-10 | |
B95 | H-FCT-95-2m-10 |