Portable Meter Meatrol Mi550 Smart Multi Function Electrical Power Analyzer

Product Details
Customization: Available
After-sales Service: 5 Year
Warranty: 5 Year
Still deciding? Get samples of US$ 750/Piece
Request Sample
Manufacturer/Factory & Trading Company
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Plant Area
897 square meters
Management System Certification
ISO9001:2015
  • Portable Meter Meatrol Mi550 Smart Multi Function Electrical Power Analyzer
  • Portable Meter Meatrol Mi550 Smart Multi Function Electrical Power Analyzer
  • Portable Meter Meatrol Mi550 Smart Multi Function Electrical Power Analyzer
  • Portable Meter Meatrol Mi550 Smart Multi Function Electrical Power Analyzer
  • Portable Meter Meatrol Mi550 Smart Multi Function Electrical Power Analyzer
  • Portable Meter Meatrol Mi550 Smart Multi Function Electrical Power Analyzer
Find Similar Products

Basic Info.

Model NO.
Mi550
Display
Digital
Installation
Direct Connected
Usage
Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter
Electric Equipment
Three-phase Four-wire
Theory
Electronic Meter
Measured Signal
Continuous Wave
Type
Energy Meter
Certification
RoHS, ISO, CE
Customized
Customized
Current Sensor
333mv CT/ Rogowski Coil
Storage
32GB Memory,USB Disk Download
Power Quality
Voltage Swell and DIP, Waveform Display
Graphs Display
Waveform, Vector Diagram and Histogram Display
Power Supply 1
2*18650 Lithium Battery
Power Supply 2
5VDC, 2A Power Supply(Included Adaptor)
Rated Current
0-18000A
Voltage Range
0-600VAC
Current Input
BNC Connector
Voltage Input
Banana Plug
Communication Protocol
Modbus TCP, Ethernet RJ45 Port
Sampling Rate
8K Samples Per Second
Harmonic
50th in The Mean Time
Wiring System
3p4w, 3p3w, 1p2w
Frequency
45...65 Hz
Transport Package
Carton
Specification
850g (with Accessory 2kgs)
Trademark
MEATROL
Origin
China
HS Code
9030331000
Production Capacity
50000PCS/Year

Product Description

Portable Meter Meatrol Mi550 Smart Multi Function Electrical Power Analyzer
World-famous manufacturer
Three major production bases in Shanghai, Chongqing, and Zhejiang
Looking forward to in-depth communications, project cooperation, and exclusive agency
                                                                                                                            Contact:    Susan 
Portable Meter Meatrol Mi550 Smart Multi Function Electrical Power Analyzer
 
Mi550 Characteristics:
 
1 Handheld power quality analyzer
2 Built-in lithium batteries
3 Built-in 32GB memory
4 Export data from a USB flash drive
5 4 inch IPS display
6 CO2 emission factor
7 Support Chinese, English, multilingual display
8 Communication: RJ45-Ethernet, Modbus-TCP/IP
9 Data, event, 1-50 harmonic values and waveform record.
10 Graphs : waveform, vector diagram and histogram display
1)Power quality:Voltage swell and dip
(Record time, amplitude value, voltage RMS 1/2 value of each phase and voltage waveform of each phase)
2)
Waveform display Ua,Ub,Uc,Ia,Ib,Ic
Waveform reading (UDP protocol)
11 Accessories: 5pcs voltage clamp, adaptor, 5pcs magnetic probe
12 The internal electric energy chip: the world's top ADE9000 chip
 
Portable Meter Meatrol Mi550 Smart Multi Function Electrical Power Analyzer
Portable Meter Meatrol Mi550 Smart Multi Function Electrical Power Analyzer
 
Portable Meter Meatrol Mi550 Smart Multi Function Electrical Power Analyzer
Portable Meter Meatrol Mi550 Smart Multi Function Electrical Power Analyzer
  1. Product description
Mi550 handheld three phase power quality analyzer, externally connected with open type Rogowski coil or voltage type CT, it can realize none dismantling wire test, simplify test steps, save construction cost, and is more convenient for engineering test as well as the inspection and maintenance of distribution system.
  1. Support systems of single-phase and three-phase. It can measure multiple electrical parameters such as current, voltage, power factor, power, energy, and power quality parameters including harmonic, unbalance degree, voltage swell and voltage dip, etc.
  2. In addition to the measurement function, Mi550 is equipped with various records, such as waveform records and programmable interval measurement value records. To store and record data, it is internally embedded 32 GB memory card.
  3. With standard configuration of RJ45 Ethernet communication interface, through standard Modbus TCP protocol, it is compatible with various configuration systems and could transmit the electrical parameters collected by the front end to the system data center in real time.
    1. General parameters
Table 11 General parameters
Product name
Model No. Mi550
Type Handheld Three phase power quality analyzer
Application field
Application field Power analysis, Power measurement, Power quality analysis
Wiring mode
Wiring system 3P4W_4CT
3P4W_3CT
3P3W_3CT
3P3W_2CT
1P2w
Current sensor Rogowski coil
Voltage-output current clamp
Voltage access Direct access
Connected through voltage transformer
Storage
Type TF card
Capacity 32GB
Data export U disk export (U disk file is FAT32 system)
Communication
Interface RJ45- Ethernet
Protocol Modbus-TCP
Power Supply
Adapter input 5VDC, 2A
Battery Rechargeable lithium battery, specification 18650, 2 pcs, capacity about 4000mAh
Battery purely working time ≥6h
Battery charging time (off state) ≤5h
Power saving mode The brightness of the screen backlight is adjustable.
The automatic screen off time is adjustable.
Display
Size 3.97 inch
Type IPS display
Resolution ratio 480*800
Machinery
Dimention 215*130*60mm
Weight 850g
Environment
Working environment Temperature-20ºC~+55ºC, Humidity below 90% RH
Storage environment Temperature-40ºC~+70ºC, Humidity below 95% RH(non-condensing)
Altitude ≤2km
Measurement category CAT III 600V
IP code IP30
 
    1. Measurement parameters
Table 12 Measurement parameters
Real-time measurement data
Voltage Phase voltage: Phase ABC
N phase to ground voltage
Line voltage: UAB, UBC, UCA
Voltage peak coefficient: Phase ABC
Voltage peak: Phase ABC
Current Phase current: Phase ABCN
Current peak coefficient: Phase ABC
K Factor: Phase ABC
Frequency Line frequency
Power Active power: Phase ABC and total
Reactive power: Phase ABC and total
Apparent power: Phase ABC and total
Power factor Phase ABC and total
Fundamental harmonic power factor Phase ABC and total
Electrical energy Active Energy: Phase ABC and total (import / export)
Reactive energy: Phase ABC and total (import / export)
Apparent Energy: Phase ABC and total
CO2 emissions
Harmonic measurement data
Voltage harmonics THD (Total harmonic percentage), TOHD (Odd total harmonic percentage), TEHD (Even total harmonic percentage), phase ABC 1-50th harmonic percentage, phase ABC 1-50th harmonic voltage value
Current harmonics THD (Total harmonic percentage), TOHD (Odd total harmonic percentage), TEHD (Even total harmonic percentage), phase ABC 1- 50th  harmonic percentage, phase ABC 1-50th harmonic current value
Waveform
Voltage waveform Phase ABC voltage waveform or UAB, UBC, UCA line voltage waveform
Current waveform Phase ABC current waveform
Phase angle
Voltag pehase angle Phase ABC
Current pehase angle Phase ABC
Phase angle between voltage and current Phase ABC
Unbalance
Unbalance Voltage unbalance, current unbalance
Demand
Power demand and peak demand Phase ABC active power and total power, phase ABC reactive power and total power, phase ABC apparent power and total power
Current demand and peak demand Phase ABC

 

    1. Parameter accuracy
Table 13 Parameter accuracy
Parameter Type Description
Voltage Channel input voltage range 0-600VAC
Measurement range 0-600VAC 
Measurement accuracy 0.2%
Current Channel input voltage range 0-420mVAC
Measurement range Different current sensors have different measuring ranges
Measurement accuracy 0.2%+ Accuracy of current sensor
Frequency Measurement range 45Hz-65Hz
Measurement accuracy ±0.001Hz
Power factor Measurement range -1-+1
Measurement accuracy ±0.005
Power Active power accuracy 0.5%
Reactive power accuracy 1%
Apparent power accuracy 0.5%
Energy Active energy accuracy 0.5%
Reactive energy accuracy 1%
Apparent energy accuracy 0.5%
    1. Record storage
Table 14 Record storage
Data record
Record name Settable
Record start time Settable
Record duration Selectable
Recording interval Settable
Basic data record Phase voltage
Line voltage
Current
Frequency
Power factor
Fundamental harmonic power factor
Power(Active, Reactive, Apparent)
Active Energy (Import energy, Export energy)
Reactive energy (Import energy, Export energy)
Apparent Energy
Voltage harmonics (Total harmonic, odd total harmonic, even total harmonic)
Current harmonics (Total harmonic, odd total harmonic, even total harmonic)
Phase voltage peak
Peak factor of phase voltage
Current crest factor
Current K factor
Voltage unbalance (negative sequence, zero sequence)
Current unbalance (negative sequence, zero sequence)
Angle (phase voltage angle, phase current angle, angle between voltages, angle between currents, angle between voltages and currents)
Max min (Phase voltage, Line voltage, Current, Frequency, Power factor, Fundamental harmonic power factor, Active power, Reactive power, Apparent power)
Demand (Current, Active power, Reactive power, Apparent power)
Peak Demand (Current, Active power, Reactive power, Apparent power)
Voltage harmonic data record Voltage harmonics (Total harmonic distortion THD, Odd total harmonic TOHD, Even total harmonic TEHD, 1-50th Harmonic percentage and voltage value)
Current harmonic data record Current harmonics (total harmonic distortion THD, Odd total harmonicTOHD, Even total harmonic TEHD, 1-50th Harmonic percentage and current value)
Data storage format CSV
Event record [[1]]
Recorded data Event type
Start time
Duration
Amplitude value
Data storage format CSV
Waveform recording
Record name Settable
Record the start time Settable
Record the duration Settable
Sampling rate Settable
Logged data Phase ABC voltage waveform
Phase ABC current waveform
Data storage format CSV
 
Portable Meter Meatrol Mi550 Smart Multi Function Electrical Power Analyzer
Safety and warning notes

In order to guarantee safe operation of the transducer and to be able to make proper use of all features and functions,please read these instructions thoroughly! Safe operation can only be guaranteed if the transducer is used for the purpose it has been designed for and within the limits of the technical specifications. Ensure you get up-to-date technical information that can be found in the latest associated datasheet under Rogowski website.

Portable Meter Meatrol Mi550 Smart Multi Function Electrical Power Analyzer
Portable Meter Meatrol Mi550 Smart Multi Function Electrical Power Analyzer


Portable Meter Meatrol Mi550 Smart Multi Function Electrical Power Analyzer

Portable Meter Meatrol Mi550 Smart Multi Function Electrical Power AnalyzerPortable Meter Meatrol Mi550 Smart Multi Function Electrical Power Analyzer

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier