Still deciding? Get samples of $ !
Request Sample
|
| Customization: | Available |
|---|---|
| Type: | Rogowski |
| Output Signal Type: | Analog Output |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
|
Advantage • Calibrated to 0.5% • 6mm section make more stable • Easy to fixed on bus-bar or cable by cable ties • Very competitive price Related Products S1 D1 S9 SW A01 A05 ME631 ME432 |
Applications
|
| MODEL | TRC-16 | TRC-24 | TRC-36 | |
| Coil length | 80mm | 97mm | 130mm | |
| Window size | 16mm | 24mm | 36mm | |
| Reference Rated current |
100A | 300A | 600A | |
| Weight | Approx 80-100g | |||
| Coil Resistance | from 100 to 300 Ω | |||
| Maximum current measurable | 100kA | |||
| Coil Section | 6mm | |||
| Lead length | 2meter | |||
| Output (di/dt) | Uncalibrated | 60mV/kA@50Hz 72mV/kA@60Hz | ||
| Calibrated | 50mV/kA@50Hz 60mV/kA@60Hz | |||
| Read Accuracy | Calibrated <0.5% (central position, 25ºC) Uncalibrated < 5% tolerance (central position, 25ºC) |
|||
| Temperature | Uncalibrated 200ppm/ºC | |||
| Calibrated 300ppm/ºC | ||||
| Position Error | ±1% maximum | |||
| Output on 0A (zero drift) | ≤0.05mV | |||
| Phase error | ≤0.5° | |||
| Linearity | ±0.2% of reading | |||
| Bandwidth | 1Hz to 100kHz(-3dB) | |||
| Operating temperature | -30ºC to 80ºC | |||
| Storage temperature | -40ºC to 90ºC | |||
| Other requirements, please contact us to OEM. | ||||
| Conductor Position | Typical Error(%) |
| Adjacent to the center of coil | <0.5% |
| Adjacent to the inside coil | <1% |
| Coil & cable | Thermoplastic rubber flame retardant UL 94 V-0 rated |
| Couplings | PC,ABS Flame-Retardant |
| Color(coil) | Black, Yellow, Red, Green, Blue |
| Shielded | 100% coil, 100% output cable |
| Certifications | CE marked |
| Complies with LVD EN 61010-1:2010 EMC EN 61326-1:2013 |
|
| IP65 | |
| Voltage insulation | Coil: 2000V |
| Signal cable:1000V | |
| Safety | 1000V CATIII ,600V CATIV |
| Dimensions(mm) | TRC-16 | TRC-24 | TRC-36 |
| A.Windows size A | 22 | 27.5 | 36 |
| B.Windows size B | 16 | 24 | 37 |
| C.Coil O.D. | 34 | 39.5 | 48 |
| D.Coil section | 6 | ||
| E.Lead Cable Total Length | 2000 | ||
| F:Coil length | 80 | 97 | 130 |
| Description | Connector model | Window size B | Signal cable length E | Ratio | Model No. | |
| Calibrated (mV/kA@50Hz) |
Uncalibrated (mV/kA@50Hz) |
|||||
| Ø 6 Mini type with fixing ribbon ties |
MRC | 16 | 2m | 50 (60mV/kA@60Hz) |
60 (72mV/kA@60Hz) |
MRC-16-2m-50 |
| 24 | MRC-24-2m-50 | |||||
| 36 | MRC-36-2m-50 | |||||
| Ø8 Rotate bayonet type Easy installation with fixing ribbon ties |
NRC | 100 | 2m | 85 | 105 | NRC-100-2m-85 |
| 150 | 85 | NRC-150-2m-85 | ||||
| 200 | 50 | NRC-200-2m-50 | ||||
| Ø12 High Voltage 36kV |
D-SRC | 50 | 2m | ________ | 60 (72mV/kA@60Hz) |
D-SRC-50-2m-60 |
| 100 | D-SRC-100-2m-60 | |||||
| 150 | D-SRC-150-2m-60 | |||||
| Ø12 High Sensitivity | SRC | 50 | 2m | 333 | 360 | SRC-50-2m-333 |
| 100 | SRC-100-2m-333 | |||||
| 150 | SRC-150-2m-333 | |||||
| Ø 6 precision type | TRC | 16 | 2m | 50 | 60 | TRC-16-2m-50 |
| 24 | TRC-24-2m-50 | |||||
| 36 | TRC-36-2m-50 | |||||
| Ø8 Snap-in type Easy installation |
ZRC | 50 | 2m | 100 / 85 / 50 | 105 | ZRC-50-2m-85 |
| 100 | ZRC-100-2m-85 | |||||
| 150 | ZRC-150-2m-85 | |||||
| Ø8 Spiral joint Suitable for long term stable installation |
Y-FCT | B50 | 2m | 85 | 110 | Y-FCT-B50-2m-85 |
| B100 | 85 | Y-FCT-B100-2m-85 | ||||
| B150 | 85 | Y-FCT-B150-2m-85 | ||||
| B240 | 50 | Y-FCT-B240-2m-50 | ||||
| Ø8 High Frequency | H-FCT | B50 | 2m | 1.2 / 6.8 / 10 | H-FCT-B50-2m-10 | |
| B95 | H-FCT-95-2m-10 | |||||