Type: Rogowski
Output Signal Type: Digital Output
Production Process: SemiConductor Integrated
Material: Metal
Accuracy Grade: 0.5G
Application: Soft Switch
Customization:
Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
MRC-24
IP Rating
IP67
Certification
CE
Customized
Customized
Transport Package
Carton
Specification
Approx. 140g
Trademark
MEATROL
Origin
Shanghai
HS Code
8504500000
Production Capacity
1000

Product Description

MRC Ø6 Flexible Rogowski coil fixed by cable ties
High linearity from 1A  to 100kA
Wide dynamic range
Very useful with large size or awkward shaped conductors or in places with limited access
No danger from open-circuited secondary
Not damaged by large overloads
Non-intrusive, no power drawn from the main
Measurement uniformity at any position of the conductor inside the coil

Excellent degree of rejection to the external current conductor
Feature
  NRC is a flexible current transducer based on Rogowski principle, particularly suitable for measurement in combination with portable devices. NRC coils are available in different sizes and can be supplied according to customer's design, therefore they can be used in all those applications, in which traditional transducers are not fitting due to its size and/or weight.
  Due to its specific features, flexible Rogowski coil is an extremely comfortable solution for current measurement and can be used in a number of cases where traditional current transducer is not the adequate solution.
  NRC coil is provided with a shield against the influence of external magnetic fields; therefore, it grants a stable measurement from low currents to hundreds of kA. The  Rogowski coils must be connected to an electronic integrator for 90° phase shift compensation and frequency equalization. Our DIN-RAIL and panel meters can interface  Rogowski coils directly without the need of the external integrators. This is an advantage because there are no external boxes or any power supply with consequent ease of use. The particular features of the Rogowski coils combined with the extremely flexible input programming of our portable meters, allow to carry out measurement by all applications.


What is a Rogowski coil?
    Rogowski coils have been used for the detection and measurement of electric currents for decades.The are based on a simple principle :an "air-cored"coil is placed around the conductor in a toroidal fashion and the manetic field produced by the current induces a voltage in the coil.The voltage out put is proportional to the rate of change of current .This voltage is integrated,thus producing an output is proportional to the rate of change of current.This voltage is integrated,thus producing an output proportional to the current.
  By using precision winding techniques,especially developed for the purpose,the coils are manufactured so that their output is not infiuenced by the position of the conductor within the toroid ,and to reject interference from external magnetic fields caused,for example ,from nearby conductors.Basically ,a Rogowski coil current measuring system consists of a combination of coil and conditioning electronics.Rogowski coil current measuring system consists of a combination of a combinaion of coil and conditioning electronics.Rogowski coil current transducers are used for the AC measurement They can be used in similar circumstances to current transformers but for many applications they have considerable advantages:
Wide dynamic range.
High linearity.
Very useful with large size or awkward shaped conductors or in places with limited access. Thanks to the structure without hard core, the coil can be easily manufactured according to the application or to the available space.
Unlike traditional current transducers, there is no danger from open-circuited secondaries.
They cannot be damaged by large overloads.
They are non-intrusive. They draw no power from the main circuit carrying the current to be measured.
They are also light weighted and in some applications are light enough to be suspended on the conductor being measured.
MODEL MRC-16 MRC-24 MRC-36
Coil length 80mm 97mm 130mm
Window size 16mm 24mm 36mm
Reference
Rated current
100A 300A 600A
Coil Resistance 55 (+/-10) Ω 65 (+/-10) Ω 80 (+/-10) Ω
Weight Approx. 100g Approx. 102g Approx. 105g
Maximum current measurable 100kA
Coil Section 6mm
Lead length 2 meter
Output (di/dt) Uncalibrated 60mV/kA@50Hz  72mV/kA@60Hz  
Calibrated 50mV/kA@50Hz  60mV/kA@60Hz
Read Accuracy Calibrated <0.5% (central position, 25ºC)
Uncalibrated < 5% tolerance (central position, 25ºC)
Temperature Uncalibrated  200ppm/C
Calibrated  300ppm/C
Position Error ±1% maximum
Output on 0A
(zero drift)
0.05mV
Phase error ≤0.5°
Linearity ±0.2% of reading
Bandwidth 1Hz to 100kHz(-3dB)
Operating temperature -30ºC to 80ºC
Storage temperature -40ºC to 90ºC
For other requirements, please contact us for customization.
Dimensions(mm) MRC-16 MRC-24 MRC-36
  1. Window size A
22 27.5 36
  1. Window size B
16 24 37
  1. Coil O.D.
34 39.5 48
  1. Coil section Diameter
6
  1. Lead Cable Total Length
2000
  1. Coil length
80 97 130
Free Installation of Sensors Flexible Rogowski Coil Reliable Rogowski Coil
Safety and warning notes
In order to guarantee safe operation of the transducer and to be able to make proper use of all features and functions, please read these instructions thoroughly! Safe operation can only be guaranteed if the transducer is used for the purpose, it has been designed for and within the limits of the technical specifications. 
Caution! Risk of danger
Ignoring the warnings can lead to serious injury and/or cause damage!
The electric measuring transducer may only be installed and put into operation by qualified personnel that have received an appropriate training, The corresponding national regulations shall be observed during installation and operation of the transducer and any electrical conductor. The transducer shall be used in electric/electronic equipment the respect to applicable standards and safety requirements and in accordance with all the related systems and components manufacturers' operating instructions.
Caution! Risk of electrical shock
When operating the transducer, certain parts of the module may carry hazardous live voltage (e.g., Primary conductor). The user shall ensure to take all measures necessary to protect against electrical shock. The transducer is a build-in device containing conducting parts that shall not be accessible after installation. A protective enclosure or additional insulation barrier may be necessary. Installation and maintenance shall be done with the main power supply disconnected except if there are no hazardous live parts in or in close proximity to the system and if the applicable national regulations are fully observed.
Safe and trouble-free operation of this transducer can only be guaranteed if transport, storage and installation are carried out correctly and operation and maintenance are carried out with care.
Caution! Risk of electrical shock
Do not apply around or remove from uninsulated hazardous live conductors which may result in electric shock, electric burn or arc flash.
WARING!
Do not stress the coil by applying any kind of mechanical force (transport, storage pressure, tight bending.) which will dramatically degrade the device's accuracy.Free Installation of Sensors Flexible Rogowski Coil Reliable Rogowski Coil


Free Installation of Sensors Flexible Rogowski Coil Reliable Rogowski Coil

Model No. Definition
Description Connector model Window size B Signal cable length E Ratio Model No.
Calibrated
(mV/kA@50Hz)
Uncalibrated
(mV/kA@50Hz)
Ø 6 Mini type
with fixing ribbon ties
MRC 16 2m 50
(60mV/kA@60Hz)
60
(72mV/kA@60Hz)
MRC-16-2m-50
24 MRC-24-2m-50
36 MRC-36-2m-50
Ø8 Rotate bayonet type
Easy installation
with fixing ribbon ties
NRC 100 2m 85 105 NRC-100-2m-85
150 85 NRC-150-2m-85
200 50 NRC-200-2m-50
Ø12 High Voltage
36kV
D-SRC 50 2m ________ 60
(72mV/kA@60Hz)
D-SRC-50-2m-60
100 D-SRC-100-2m-60
150 D-SRC-150-2m-60
Ø12 High Sensitivity SRC 50 2m 333 360 SRC-50-2m-333
100 SRC-100-2m-333
150 SRC-150-2m-333
Ø 6 precision type TRC 16 2m 50 60 TRC-16-2m-50
24 TRC-24-2m-50
36 TRC-36-2m-50
Ø8 Snap-in type
Easy installation
ZRC 50 2m 100 / 85 / 50 105 ZRC-50-2m-85
100 ZRC-100-2m-85
150 ZRC-150-2m-85
Ø8 Spiral joint
Suitable for long term stable installation
Y-FCT B50 2m 85 110 Y-FCT-B50-2m-85
B100 85 Y-FCT-B100-2m-85
B150 85 Y-FCT-B150-2m-85
B240 50 Y-FCT-B240-2m-50
Ø8 High Frequency H-FCT B50 2m 1.2 / 6.8 / 10   H-FCT-B50-2m-10
B95   H-FCT-95-2m-10
COMPANY INTRODUCTION
Free Installation of Sensors Flexible Rogowski Coil Reliable Rogowski Coil
Free Installation of Sensors Flexible Rogowski Coil Reliable Rogowski Coil
Free Installation of Sensors Flexible Rogowski Coil Reliable Rogowski Coil
Free Installation of Sensors Flexible Rogowski Coil Reliable Rogowski Coil

For more detailed information, please contact us by email

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Plant Area
897 square meters
Management System Certification
ISO9001:2015