• Meatrol Mq21 Rogowski Digital Energy Meter Kwh Meter Energy Analyzer
  • Meatrol Mq21 Rogowski Digital Energy Meter Kwh Meter Energy Analyzer
  • Meatrol Mq21 Rogowski Digital Energy Meter Kwh Meter Energy Analyzer
  • Meatrol Mq21 Rogowski Digital Energy Meter Kwh Meter Energy Analyzer
  • Meatrol Mq21 Rogowski Digital Energy Meter Kwh Meter Energy Analyzer
  • Meatrol Mq21 Rogowski Digital Energy Meter Kwh Meter Energy Analyzer

Meatrol Mq21 Rogowski Digital Energy Meter Kwh Meter Energy Analyzer

After-sales Service: 1 Year
Warranty: 1 Year
Display: Color OLED
Installation: DIN Rail
Usage: Multi-Functional Energy Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Maximum Demand Meter
Electric Equipment: Three-phase Four-wire
Samples:
US$ 400/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
MQ21
Theory
Electronic Meter
Power Meter Connection
Terminal
Measured Signal
Rogowski Coil, Voltage-Output Current Clamp
Type
Energy Meter
Certification
RoHS, ISO, CE
Customized
Customized
Application
Power Analysis/Energy Measure/ Event Data Record
Supported Current Sensor
Rogowski Coil, Voltage-Output Current Clamp
Storage
16GB Micro SD Card, USB Data Download
Primary Side Current Range
600A, 3000A, 6000A
Power Supply
Electricity From Major Loop, 90-528VAC
Connecting Terminal Type
SATA Interface, Terminals
ABC Voltage Measurement Accuracy
0.2%(5-528V AC)
Temperature
3 Channels(Optional)
Humidity
1 Channel
Frequency
0.01%(45-65Hz)
Communication
Modbus TCP & Modbus RTU
Harmonic
51 Times
Data Format
Csv
Optional 1
on-Line Power Quality Monitoring Platform
Optional 2
4G Edge Processing Gateway
Transport Package
Poly Bag and Stand Export Carton
Specification
13*9.5*5.6CM
Trademark
MEATROL
Origin
China
HS Code
9030331000
Production Capacity
50000PCS/Year

Product Description

Meatrol Mq21 Rogowski Digital Energy Meter Kwh Meter Energy Analyzer
 
Technical consultant
                                                                                                                                                                    Susan 
 
Meatrol Mq21 Rogowski Digital Energy Meter Kwh Meter Energy Analyzer
 
Meatrol Mq21 Rogowski Digital Energy Meter Kwh Meter Energy Analyzer
Meatrol Mq21 Rogowski Digital Energy Meter Kwh Meter Energy Analyzer

1   Product description

MQ21, the power quality analyzer externally connected with open type Rogowski coil or voltage CT, it can realize no dismantling wire test, facilitate engineering test, simplify test steps, save construction cost, and is also more convenient for the inspection and maintenance of distribution system. MQ21 supports systems of single-phase and three-phase: it can measure multiple electrical parameters such as voltage, current, harmonic, energy, power factor and active power on the power grid of phase A, B, C and phase N. With standard configuration of RJ45 and RS485 communication interfaces, through standard Modbus TCP and Modbus RTU protocols, it can be compatible with various configuration systems and transmit the electrical parameters collected by the front end to the system data center in real time.
 
Description
Model No. MQ21
Type Three phase power quality analyzer
Supported types of current sensor Rogowski coil, Voltage-output current clamp
Wiring mode 3ф_WYE_4CT, 3ф_WYE_3CT, 3ф_DELTA_3CT,3ф_DELTA_2CT,1ф
Storage 16GB Micro SD card,USB data download
(default storage interval: 1 minute)
Harmonic 51 times  
Application power analysis,  energy measurement
Display screen 1.3-inch color OLED
Weight Approx 400g
Dimension L*W*D:13*9.5*5.6CM
Color White
Input current
Primary side current range 600A       0.5A ~ 720A
3kA        0.5A ~ 3600A
6kA        0.5A ~ 7200A
Secondary side current range(ST08  current clamp or the same type) 1mA~10A
Input voltage value 1/225mV~707mV
Overload capacity 2V,10s/hours
Power supply
Electric source Electricity from major loop, 90~528VAC
External battery External 18650 lithium battery
Power consumption
Max power consumption 2.5W
Connecting terminal type
ABC phase current input SATA interface
N-phase current input 5.08 terminal
Voltage input 7.62 spacing terminals
Power supply Electricity from major loop, 90~528V

2   Function

Measurement
Voltage UA,UB,UC,and average value
Current IA,IB,IC,IN and average value
Power Active power, reactive power, apparent power (each phase, sum value of three phases)
energy Active energy, reactive energy, apparent energy(each phase, sum value of three phases)
Exceeds 999.9GWh, energy value cleared to "0" automatically
Line voltage Between phases
Angle between line voltages Between phases
Angle between currents Between phases
Power factor Including harmonic power factor PF and fundamental power factor DPF(each phase, average value of three phases)
Max / Min.
Voltage Each phase, average value of three phases
Current Each phase, average value of three phases
Power Active power, reactive power, apparent power(each phase, sum value of three phases)
Unbalance degree
Voltage Each phase, the max unbalance degree of three phases        
Current Each phase, the max unbalance degree of three phases        
Demand / Max Demand
Current Each phase, average value of three phases
Power Active power, reactive power, apparent power(each phase, sum value of three phases)
Temperature and humidity
Temperature 3 channels(optional)
Humidity 1 channel
Power quality
Voltage swell Start time, end time, amplitude value
Voltage dip Start time, end time, amplitude value
Voltage harmonic value and percentage Total harmonic, 1, 2, 3, 4... 51 (51st) harmonics
Current harmonic value and percentage Total harmonic, 1, 2, 3, 4... 51 (51st) harmonics
 
General data record
Record interval setting 5 ~ 9999s (default 60s)
Data format CSV
Storage capacity Micro SD card: 16GB
Storage duration: 3 years (using 16GB SD card, once / 60s)
Recorded data Basic data
Voltage harmonic
Current harmonic
Event data record
Data format CSV
Recorded data Event type
Start time
Duration
Amplitude value
Voltage RMS 1 / 2 value of each phase
Voltage waveform of each phase

3   Accuracy and certification

Measurement accuracy
Rogowski coil Current measurement accuracy 0.5%(1%~120% rated current)
(<10A, accuracy not guaranteed)
Current gear 600A(6A~720A): TRC-36 (50mV/kA@50Hz)
3000A(10A~3600A): NRC-150 (85mV/kA@50Hz)
6000A(20A~7200A): NRC-200 (50mV/kA@50Hz)
ST08 current clamp Current measurement accuracy 0.5%(100mA~10A)
1%(10mA~100mA), (<10mA, accuracy not guaranteed)
ABC Voltage measurement accuracy 0.2%(5~528V AC)
Power factor ±0.005
Active and apparent power IEC62053-22  Class 0.5S
Reactive power IEC62053-21  Class 2S
Frequency 0.01%(45~65Hz)
Active energy IEC62053-22  Class 0.5S
Reactive energy IEC62053-21  Class 2S
Environment condition
Operating temperature -25ºC~+55ºC
Storage temperature -40ºC~+85ºC
Humidity range 5~95% RH, 50ºC (non-condensing)
Pollution Level 2
Overvoltage capacity III, applicable to the distribution system below 277/480VAC
Insulation strength IEC61010-1
Altitude 3000m Max
Anti-pollution level IP20(conforming to IEC 60629)
Products expiry 24 months
EMC(Electromagnetic compatibility)
Electrostatic discharge Level IV(IEC61000-4-2)
Radiation Immunity Level III (IEC61000-4-3)
EFT Electrical Fast Burst Immunity Level IV (IEC61000-4-4)
Surge immunity Level IV (IEC61000-4-5)
Immunity to Conducted Disturbance Level III (IEC61000-4-6)
Power frequency magnetic field immunity 0.5mT (IEC61000-4-8)
Conduction and radiation Class B (EN55022 )
Standard compliance
EN 62052-11, EN61557-12, EN 62053-21, EN 62053-22, EN 62053-23, EN 50470-1, EN 50470-3, EN 61010-1, EN 61010-2, EN 61010-031

4   Outline and dimensions

Meatrol Mq21 Rogowski Digital Energy Meter Kwh Meter Energy Analyzer

5   Port definition

MQ21 is equipped with abundant interfaces to realize different functions.
Meatrol Mq21 Rogowski Digital Energy Meter Kwh Meter Energy Analyzer

5.1   Power supply

MQ21 is powered directly through ABCN voltage channel. The power supply voltage range: 90~528VAC, 45~60Hz, Mam power consumption 2.5W.
  • Do not connect the analyzer when the cable is live;
  • Before connecting the power supply, be sure to confirm whether the power supply voltage is within the required range, otherwise the analyzer cannot work normally.

5.2   Voltage current input

The analyzer supports 5 wiring modes: 3ф_WYE_4CT, 3ф_WYE_3CT, 3ф_DELTA_3CT, 3ф_DELTA_2CT, Single phase.
 
  • The actual wiring mode of the analyzer must be consistent with the one configured inside the analyzer.
  • 3ф_WYE_4CT need 4pcs current sensor, and N-phase current can be measured.
  • 3ф_WYE_3CT need 3pcs  current sensor, N-phase current cannot be measured.
  • 3ф_DELTA_3CT need 3pcs current sensor, phase B current is acquired by sensor actual measurement.
  • 3ф_DELTA_2CT need 2pcs current sensor, phase B current is acquired by calculating.
  • The phase sequence of voltage and current must correspond one by one, otherwise the measured data of the analyzer is incorrect.
  • When using the current sensor, note that the direction of the current arrow on the sensor must be consistent with the actual current flow, that is, the sensor current arrow points to the load end.
 
For more information, please refer to MQ21 manual. 

More additional pleasantly surprised products:

Meatrol Mq21 Rogowski Digital Energy Meter Kwh Meter Energy AnalyzerMeatrol Mq21 Rogowski Digital Energy Meter Kwh Meter Energy Analyzer
 Meatrol Mq21 Rogowski Digital Energy Meter Kwh Meter Energy Analyzer

Meatrol Mq21 Rogowski Digital Energy Meter Kwh Meter Energy Analyzer
Meatrol Mq21 Rogowski Digital Energy Meter Kwh Meter Energy Analyzer
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Plant Area
897 square meters
Management System Certification
ISO9001:2015